Temperature Range | 0 to 750 deg C |
Accuracy | +/- 2.5 deg C or +/- 0.75%) |
Class | Class 2 |
Probe Material | Stainless Steel |
Application | Industrial |
Assembly | Thermocouple Probe |
Mount | Bayonet |
Probe Termination | Jack |
Probe Diameter | 0.5 - 8 mm |
Probe Length | 0 - 150 mm |
Junction Type | Grounded |
A Bayonet Thermocouple is a type of thermocouple which uses a Bayonet type mounting for process connection.
It can be said Bayonet mount or a Bayonet Fastener is a fastening mechanism which consists of a cylindrical male side with pins mounted radially, and a female receptor with L-shaped slot(s) which matches the pins and with spring(s) which forces the parts to stick together.
Type J thermocouple is a very common and general purpose thermocouple. It has smaller temperature range and a shorter lifespan at higher temperatures. It consist of positive leg made of an Iron wire and negative leg made of an Constantan ( Copper-Nickel ) alloy wire.
Minimum Order Quantity | 5 Piece |
Temperature Range | 0 to 1300 deg C |
Accuracy | +/- 1.5 deg C or +/- 0.25% |
Class | Class 2 |
Probe Material | Stainless Steel |
Application | Industrial |
Assembly | Thermocouple Head Assembly |
Probe Diameter | 0.5 - 8 mm |
Mount | Tube Skin |
Probe Termination | Head Assembly |
Probe Length | 0 - 150 mm |
Application:
Properties:
Minimum Order Quantity | 1 Piece |
Class | Class 1 |
Material | Stainless Steel |
Country of Origin | Made in India |
Temperature Range | 0 to 1300 deg C |
Accuracy | +/- 1.5 deg C or +/- 0.25% |
Class | Class 2 |
Probe Material | Stainless Steel |
Probe Diameter | 0.5 - 8 mm |
Probe Length | 0 - 150 mm |
Application | Industrial |
Assembly | Thermocouple Probe |
Mount | Bayonet |
Probe Termination | Lead Wire |
Junction Type | Ungrounded |
Type S Thermocouple (Platinum Rhodium - 10% / Platinum): The Type S is used in very high temperature applications. It is commonly found in the BioTech and Pharmaceutical industries. It is sometimes used in lower temperature applications because of its high accuracy and stability. The type S is often used with a ceramic protection tube.
Type S Temperature Range:
Maximum continuous operating temperature: up to 2,912F (1600C)
Short term use: up to 3,092F (1,700C)
Type S Thermocouple Grade WireThermocouple grade wire, -58 to 2700F (-50 to 1480C)
Extension wire, 32 to 392F (0 to 200C)
Accuracy (whichever is greater):
Standard: +/- 1.5C or +/- .25%
Special Limits of Error: +/- 0.6C or 0.1%
Fixed Immersion: